Solutions
Horse Construction offers full range of structural strengthening materials with technical supports, documentation supports, products supports, project supports.
FRP Strengthening Limits

Fiber reinforced polymer (FRP) composite systems have been widely adopted for external strengthening of concrete structural members to upgrade flexural, shear and confinement performance. Nevertheless, ACI 440 design specifications establish a fundamental safety principle: FRP functions as additional supplementary reinforcement, or a secondary line of defense, rather than the primary load-bearing component of the structure.

This philosophy sets mandatory strengthening limits to avoid catastrophic collapse if the FRP system loses its load-carrying capacity.
Normal Service Limit State: Original Member Provides Primary Backup
Under ordinary service conditions, engineers must verify that the original unreinforced concrete member can resist the increased design load combination, even assuming complete debonding, damage or loss of the FRP reinforcement.
The underlying logic is straightforward: FRP may suffer from bonding failure, vandalism, mechanical damage or long-term degradation. If FRP is the main load-resisting component, sudden FRP failure will trigger brittle structural collapse. The strengthening limit check defined in ACI 440 Chapter 9 ensures the original structure retains sufficient residual capacity to sustain upgraded loads before damaged FRP can be repaired.
Fire Limit State: FRP Is Assumed Inactive Under Elevated Temperatures
Polymeric resins and adhesives used for externally bonded FRP lose mechanical and bonding properties once temperature approaches or exceeds the glass transition temperature (Tg). In fire design assessments, FRP contribution is by default neglected.
Global Load Path and Ductile Failure Control
Two further critical requirements complement this secondary-defense design concept.
First, the full load transfer path must remain intact. FRP increases the load capacity of local strengthened members; all related structural components along the load path, including columns, slabs and footings, shall be checked to withstand the amplified load effects. Local member upgrade cannot compromise the safety of the overall structural system.
Second, failure mode control is required. The strengthened member shall fail in a ductile flexural mode under overload, rather than brittle shear failure. This “strong shear, weak bending” requirement prevents sudden, explosive shear collapse and maintains predictable warning before structural failure.

Summary
FRP external strengthening delivers outstanding retrofit benefits, yet designers should never transfer the full structural safety reliance onto FRP materials. By treating FRP as secondary supplementary reinforcement, implementing strengthening limits for normal and fire conditions, verifying global load path integrity, and enforcing ductile flexural failure, engineers can achieve robust, code-compliant, safe FRP retrofit solutions for concrete infrastructure.
You can find anything here you are in need of, have a trust trying on these products, you will find the big difference after that.